T510 series inverter adopt speed sensorless vector control technology, the product has excellent driving performance and control functions; the product has rich hardware configuration, powerful softwa...
Machine tool、Cable machinery、Petrochemical industry 、Textile industry、Food packaging、Eluting equipment、Centrifuge etc
T510 series inverter adopt speed sensorless vector control technology, the product has excellent driving performance and control functions; the product has rich hardware configuration, powerful software functions, and has a greater improvement in ease of use and reliability, which can better meet the different needs of various industrial control occasions. T510 series 0.75~18.5kw built-in standard braking unit, 22~90kw selected built-in braking unit, the whole series of independent duct design, improve product reliability and performance, enhance product competitiveness.
Item |
Specifications |
||
Basic functions |
Maximum frequency |
Vector control: 300.00Hz |
|
Carrier frequency |
0.5kHz-16kHz, The carrier frequency can be adjusted automatically based on the load features. |
||
Input frequency resolution |
Digital setting: 0.01Hz |
||
Control mode |
Open-loop vector control (SVC) |
||
Start-up torque |
G type: 0.5Hz/150% (SVC), 0Hz/180% (FVC) |
||
Speed range |
1:100 (SVC) |
1:1000(FVC) |
|
Steady speed accuracy |
±0.5%(SVC) |
±0.02%(FVC) |
|
Torque control accuracy |
±5%(FVC) |
||
Overload capacity |
G type: 150% rated current 60s; 180% rated current 3S P type: 120% rated current 60s; 150% rated current 3S |
||
Automatic torque lifting |
Manual torque lifting 0.1%-30.0%. |
||
Three ways of V/F curve |
Straight-line type; |
||
Two ways of V/F separation |
Two types: complete separation and half separation |
||
Ramp mode |
Straight-line ramp or S-curve ramp, Four groups of acceleration /deceleration time with the range of 0.0s-6500.0s |
||
DC braking |
0.00Hz - maximum output frequency, |
||
JOG control |
JOG frequency range: 0.00Hz-50.00Hz, |
||
On board multiple preset speeds |
It implements up to 16 speeds via the simple PLC function or combination of DI terminal states. |
||
Built-in PID |
It realizes process-controlled closed-loop control system easily. |
||
Automatic voltage adjustment (AVR) |
It can keep constant output voltage automatically when the main voltage changes. |
||
Torque limitation and control |
It cam limit the torque automatically and prevent frequent over current tripping during the running process. |
||
Individualized functions |
Safety self-inspection of power-on peripheral equipment |
It can realize the safety detection of peripheral equipment such as grounding, short circuit and so on. |
|
Over-voltage and over-loss speed control |
Automatic limit of current and voltage during operation to prevent frequent over-current and over-voltage tripping |
||
Fast current Limit |
Minimizing overcurrent fault and protecting frequency converter in normal operation |
||
Common DC bus function |
It can realize common DC bus functions of multiple frequency converters. |
||
QUICK key |
User-defined shortcut menu |
||
MF.K key |
Programmable key: command channel switching/forward and reverse running/JOG running function selection |
||
Textile swing frequency control |
Given length control function |
||
Timing control |
Timing control function: setting time range 0h-65535h |
||
Running channel |
Running command sources |
Three channels: operation panel, control terminal and serial communication port .They can be switched over between these sources in various ways. |
|
Frequency sources |
There are total 10 of frequency sources, such as digital setting, analog voltage setting, analog current setting,pulse setting and serial communication port setting. They can be switched over these sources in various ways. |
||
Auxiliary frequency command |
10 kinds of auxiliary frequency instructions. It can realize auxiliary frequency fine adjustment and frequency synthesis flexibly. |
||
Input terminal |
Seven digital Input terminals, of which X5 can be used as high-speed pulse input. Compatible with active PNP |
||
Output terminal |
A high-speed pulse output terminal DO (optional open collector type), 0 kHz-100 kHz square wave signal output, |
||
Display and keyboard |
LED display |
Display monitoring parameters, output frequency, set frequency, bus voltage, etc. |
|
Keyboard lock and function selection |
To realize partial or total lock of keys, define the scope of action of some keys, in order to prevent misoperation. |
||
Protection Function |
Short circuit detection , input and output phase loss protection, overcurrent protection, overvoltage protection, undervoltage protection , overheat protection and overload protection |
||
Optional parts |
Brake assembly |
||
Ambient |
Installation location |
Indoor ,free from direct sunlight, dust-free, corrosive gases, combustible gases, oil smoke, vapour, drip or salt, etc. |
|
Altitude |
<1000m |
||
Ambient temperature |
-10°C~+40°C (ambient temperature is 40°C~50°C , please derate to use) |
||
Humidity |
Less than 95 k% RH, no water droplet condensation |
||
Vibration |
less than 5.9m/s 2 (0.6g) |
||
Storage temperature |
-20℃~+60℃ |
||
IP level |
IP20 |
||
Pollution grade |
PD2 |
||
Power distribution system |
TN,TT |
Model |
Rated Capacity |
Rated Input Current(A) |
Rated Output Current(A) |
Adapted Motor (KW) |
Single-phase power supply 200~240V 50/60Hz |
||||
T510-2S0.4B |
1 |
5.4 |
2.3 |
0.4 |
T510-2S0.75B |
1.5 |
8.2 |
4 |
0.75 |
T510-2S1.5B |
3 |
14 |
7 |
1.5 |
T510-2S2.2B |
4 |
23 |
9.6 |
2.2 |
Three-phase power supply 380~480V 50/60Hz |
||||
T510-4T0.75G/1.5PB |
1.5/3 |
3.4/5 |
2.1/3.8 |
0.75/1.5 |
T510-4T1.5G/2.2PB |
3/4 |
5/5.8 |
3.8/5.1 |
1.5/2.2 |
T510-4T2.2G/3.0PB |
4/4.9 |
5.8/8.0 |
5.1/6.8 |
2.2/3.0 |
T510-4T3.0G/4.0PB |
4.9/5.9 |
8.0/10.5 |
6.8/9.0 |
3.0/4.0 |
T510-4T4.0G/5.5PB |
5.9/8.9 |
10.5/14.6 |
9/13 |
4.0/5.5 |
T510-4T5.5G/7.5PB |
8.9/11 |
14.6/20.5 |
13/17 |
5.5/7.5 |
T510-4T7.5G/11PB |
11/17 |
20.5/26 |
17/25 |
7.5/11 |
T510-4T11G/15PB |
17/21 |
26/35 |
25/32 |
11/15 |
T510-4T15G/18.5PB |
21/24 |
35/38.5 |
32/37 |
15/18.5 |
T510-4T18.5G/22P(B) |
24/30 |
38.5/46.5 |
37/45 |
18.5/22 |
T510-4T22G/30P(B) |
30/40 |
46.5/62 |
45/60 |
22/30 |
T510-4T30G/37P(B) |
40/57 |
62/76 |
60/75 |
30/37 |
T510-4T37G/45P(B) |
57/69 |
76/92 |
75/91 |
37/45 |
T510-4T45G/55P(B) |
69/85 |
92/113 |
91/112 |
45/55 |
T510-4T55G/75P(B) |
85/114 |
113/157 |
112/150 |
55/75 |
T510-4T75G/90P(B) |
114/134 |
157/180 |
150/176 |
75/90 |
T510-4T90G/110P(B) |
134/160 |
180/214 |
176/210 |
90/110 |
T510-4T110G/132P |
160/192 |
214/256 |
210/253 |
110/132 |
Shellcode |
Models |
Installation Hole Position (mm) |
Overall Dimension (mm) |
Diameter (mm) |
Weight |
||||
A |
B |
H |
H1 |
W |
D |
||||
Z1 |
T510-2S0.4B |
76 |
164 |
177 |
/ |
93 |
117 |
5.5 |
0.95 |
T510-2S0.75B |
|||||||||
T510-2S1.5B |
|||||||||
T510-4T0.75G/1.5PB |
|||||||||
T510-4T1.5G/2.2PB |
|||||||||
T510-4T2.2G/3.0PB |
|||||||||
T510-4T3.0GB |
|||||||||
Z2 |
T510-4T4.0PB |
119 |
189 |
200 |
/ |
130 |
162 |
5.5 |
|
T510-4T4.0G/5.5PB |
|||||||||
T510-4T5.5G/7.5PB |
|||||||||
Z3 |
T510-4T7.5G/11PB |
128 |
238 |
250 |
/ |
140 |
170 |
6 |
|
T510-4T11G/15PB |
|||||||||
Z4 |
T510-4T15G/18.5PB |
166 |
266 |
280 |
/ |
180 |
170 |
6 |
|
Z5 |
T510-4T18.5G/22PB |
150 |
339 |
340 |
355 |
230 |
210 |
7 |
|
T510-4T22G/30PB |
|||||||||
Z6 |
T510-4T30G/37P(B) |
200 |
413 |
415 |
430 |
274 |
245 |
7 |
|
T510-4T37G/45P(B) |
|||||||||
Z7 |
T510-4T45G/55P(B) |
245 |
523 |
525 |
542 |
300 |
300 |
10 |
|
T510-4T55G/75P(B) |
|||||||||
Z8 |
T510-4T75G/90P(B) |
270 |
560 |
554 |
580 |
338 |
340 |
10 |
|
T510-4T90G/110P |
|||||||||
T510-4T110G/132P |
|||||||||
Z9 |
T510-4T132G/160P |
|
|
|
|
|
|
|
|
T510-4T160G/200P |
|||||||||
T510-4T185G/200P |
|||||||||
Z10 |
T510-4T200G/220P |
|
|
|
|
|
|
|
|
T510-4T220G/250P |
|||||||||
Z11 |
T510-4T250G/280P |
|
|
|
|
|
|
|
|
T510-4T280G/315P |
|||||||||
Z12 |
T510-4T315G/355P |
|
|
|
|
|
|
|
|
T510-4T355G/400P |
|||||||||
T510-4T400G/450P |
|||||||||
T510-4T450G/500P |